SQUARE FRAME AXIAL FAN
EQ404
The EQ series is ideal wherever it is necessary to move large volumes of air with low heads with wall and/or panel applications, for ventilation farms, parking lots, electrical equipment, etc.
Operating temperature : -25°/+40°
Key Features
- Square frame with large suction radius protected against weathering
- Impeller with high-efficiency airfoil blades and stationary variable-setting angle, made of high-strength technopolymer and cast aluminum hub
- Steel wire motor-side safety net protected against weathering, made according to UNI EN 294 standard
- Static and dynamic balancing according to UNI/ISO 1940/BS 6861 - 1 standard
- Three-phase or single-phase asynchronous motor, EEF 1 and 2 efficiency, suitable for operation by speed regulation, IP 55 protection, class F insulation, S1 service, execution 5, conforms to IEC/EEC specifications (UNEL-MEC)
- Air flow from motor to impeller
- Supply voltage
- single-phase Volt 230 Hz 50
- three-phase Volts 230/400 Hz 50
- Clean non-abrasive ducted air
Accessories
- Cerebro and/or Easy series switchboard
- Speed controller (single phase)
- Impeller side safety net
- Gravity damper
- Spacer
On request:
- Reverse air flow (impeller to motor)
- Version with aluminum impeller
- Atex-certified version for potentially explosive environments
Technical characteristics
0,18
3PH
0,6
4
QE Cerebro/Easy 1PH Regulator
Dimensions
500X500X320
450X450
NO.4X10MM
410
9
CIMI Srl reserves the right to change dimensional dimensions and/or performance for improvements or range changes without what is on the site being binding.
The reported data meet the following parameters:
- - Tolerance on flow rate ±5%
- - Noise tolerance +3dB(A)
- - Air temperature 15°C
- - Barometric pressure 760 mm Hg
- - Air specific gravity 1.226 kg/m³
- - Frequency 50 Hz
Sound pressure level was measured by omnidirectional free-field measurement at 1.5 or 3 m (depending on the product) from the fan with ducted inlet, tolerances, performance points and environments according to European standards.
Flow rate tolerance ±5% | Noise tolerance +3dB(A) | Air temperature 15°C | Barometric pressure 760 mm Hg | Air specific gravity 1.226 Kg/m³ | Frequency 50 Hz
The sound pressure level was measured with omnidirectional free-field measurement at 1.5 or 3 m (depending on the product) from the fan with ducted inlet, tolerances, performance points and environments according to European standards."
- Square frame with large suction radius protected against weathering
- Impeller with high-efficiency airfoil blades and stationary variable-setting angle, made of high-strength technopolymer and cast aluminum hub
- Steel wire motor-side safety net protected against weathering, made according to UNI EN 294 standard
- Static and dynamic balancing according to UNI/ISO 1940/BS 6861 - 1 standard
- Three-phase or single-phase asynchronous motor, EEF 1 and 2 efficiency, suitable for operation by speed regulation, IP 55 protection, class F insulation, S1 service, execution 5, conforms to IEC/EEC specifications (UNEL-MEC)
- Air flow from motor to impeller
- Supply voltage
- single-phase Volt 230 Hz 50
- three-phase Volts 230/400 Hz 50
- Clean non-abrasive ducted air
The EQ series is ideal wherever it is necessary to move large volumes of air with low heads with wall and/or panel applications, for ventilation farms, parking lots, electrical equipment, etc.
Operating temperature : -25°/+40°
- Cerebro and/or Easy series switchboard
- Speed controller (single phase)
- Impeller side safety net
- Gravity damper
- Spacer
On request:
- Reverse air flow (impeller to motor)
- Version with aluminum impeller
- Atex-certified version for potentially explosive environments