Industrial suction
Axial
DF
The particular application of the DF series is for air mixing in all those facilities where the phenomenon of de-stratification of heat and humidity is to be eliminated, benefiting the health of the operators and reducing energy waste.
The construction of this series, equipped with adjustable motors at low speeds, prevents the formation of cold air currents on the ground. - Operating temperature : -25°C/+40°C
ED
The ED (short case) and EI (long case) series are ideal for applications where large volumes of air with low heads are needed, for suction of fumes, dusty or humid air, in foundries, cement factories, paper mills, in shipbuilding, for heat exchangers, etc.
Operating temperature : -25°/+40°
EQ
The EQ series is ideal wherever it is necessary to move large volumes of air with low heads with wall and/or panel applications, for ventilation farms, parking lots, electrical equipment, etc.
Operating temperature : -25°/+40°
Centrifugal box simple suction
CASTLE
The CASTLE series is particularly suitable for all suction systems where very low sound levels are required in the use of centrifugal single inlet fans.
- Suitable for conveying clean air or conveying suspended materials at a maximum temperature of 60°C.
- Hot gas execution on request
Centrifuges simple suction
GF
FIELDS OF WORK: Small-medium-high flow rates. Medium pressures.
TYPE OF TURN: Curved, inverted, (negative).
APPLICATIONS: For suction and conveyance of clean or dusty air, even containing sawdust, various shavings, granular materials in low quantities, excluding filamentous materials.
GR
FIELDS OF WORK: Small-medium-high flow rates. Medium pressures.
TYPE OF TURN: Curved, reverse, (negative).
APPLICATIONS: For pneumatic conveying, fumes, fi ni dust. Suitable for conveying solids mixed with air, shavings and sawdust with untraversed fan.
RH
FIELDS OF WORK: Medium flow rates and medium to high pressures.
TYPE OF ROTARY: Backward blades with cover.
APPLICATIONS: Suction and transport of clean air. Suitable for conveying solids mixed with air, chips and sawdust with fan not traversed by material.
RL
OPERATING RANGES: Medium to high flow rates and medium to low pressures.
TYPE OF TURN: Curved, reverse, negative.
APPLICATIONS: For suction of clean and slightly dusty air, for applications in industrial plant engineering and civil and industrial air conditioning
RM
FIELDS OF WORK: Low-medium-high flow rates. Low-medium pressures.
TYPE OF TURN: Curved, inverted, (negative).
APPLICATIONS: For suction and conveyance of even very dusty air, sawdust, various shavings, granular materials, excluding filamentous materials.
Antacid centrifuge
PL
The ideal use of the PL series is in conveying corrosive fluids, even with high concentrations of moisture. This series allows 12 orientation positions (8 clockwise RD and 8 counterclockwise LG), defined by looking at the fan from the motor side. Suitable for conveying clean, nonabrasive air at a maximum temperature of 60°C
Centrifuge from channel
LM
The LM series combines the typical advantage of helical fans of being able to transport air on the same axis as the impeller with the high efficiencies of a centrifugal impeller. - Ideal for 'installation on hoods and small civil and industrial extraction systems, they are characterized by low noise and discrete heads. The limited overall dimensions and normalized suction and pressure ports make the installation of this series particularly easy. Suitable for conveying clean air at a maximum temperature of 40 °C.
Double suction
DAT
The DAT series is of the centrifugal double suction transmission type with forward blade impeller
DDA
The DDA series is of the double suction centrifugal type with forward-bladed impeller and OPEN or CLOSED motor directly coupled to the impeller, can be 4-pole (1400 rpm), 6-pole (900 rpm), or three-speed (1400- 1100- 900 rpm), suitable for operation with speed regulation. The temperature of the conveyed fluid must not exceed 40° C.
DIRECT MINICASTLE
- The MiniCastle series is particularly suitable for all suction systems where very low sound levels are required in the use of double inlet centrifugal fans
- Suitable for conveying clean air at a maximum temperature of 40°C
- Equipped with a CLOSED motor directly coupled to the impeller, 4 Poles (1.400rpm), 6 Poles (900rpm), or 3-speed (1,400 - 1,100 - 900rpm), suitable for operation with speed control
- The motors mounted are asynchronous single-phase 230V 50Hz or 230/400V 50Hz class F
MINICASTLE PLUG FAN
- The MiniCastle Plug Fan series is particularly suitable for all suction systems where very low sound levels are required in the use of double inlet centrifugal fans
- Suitable for conveying clean air at the maximum temperature of 40°C
- Equipped with IEC motor directly coupled to the impeller, 4 Poles (1,400 rpm), 6 Poles (900 rpm)
- Mounted motors are asynchronous or the new motors with permanent magnets power supply 230V 50Hz - 230/400V 50Hz class F/B
MINICASTLE TRANSMISSION
MCT series fan boxes are equipped with centrifugal double inlet transmission fan. Mounted motors are asynchronous three-phase IEC V. 230/400 Hz 50 or V. 400/690 Hz 50 IP 55 CLASS F. Dual polarity 4/6 Poles motors (1,400 - 900 RPM) are available on request. The temperature of the conveyed fluid must not exceed 40°C.
SILBOX
The SILBOX series is particularly suitable for all small suction systems where very low sound levels are required combined with considerable ease of installation.
The supply and suction outlets are normalized circular. Suitable for conveying clean air at a maximum temperature of 40°C.
Axial and centrifugal spindle
TC
The TC series is used for direct or ducted rooftop suction, wherever large volumes of air need to be moved with modest heads. The construction of this series, equipped with UNEL-MEC motors, ensures long-term robustness and reliability, allowing for eventual replacement or repair of the motors, all of which are unified and built to international standards. Operating temperature: -25°C/+70°C
TE
The TE series is used wherever large volumes of air need to be extracted with rooftop applications in the absence of ductwork. The construction of this series, equipped with UNEL-MEC motors, ensures long-term robustness and reliability, allowing for eventual replacement or repair of the motors, all of which are unified and built to international standards.
Operating temperature : -25°C/+40C°